Embedded MCP server for controlling and monitoring RIGOL DP800 series power supplies. Provides read-only device queries and optional write control (voltage, current, output state, protection settings) with per-channel measurements and protection state tracking.
RigolWidget demonstrates solid tool design with clear verb-based naming (get_*, set_*, show_*), comprehensive descriptions (avg 120 chars), and proper parameter typing. All 9 tools have input schemas with typed parameters and descriptions. Tool annotations (ReadOnly, Destructive, Idempotent, OpenWorld) are well-applied. However, output schemas are not explicitly documented in the visible code, return types are inferred from method signatures (IdentityResult, StatusResult, string). Parameter descriptions are adequate but lack explicit constraints (e.g., channel must be 1-3, no enum for 'kind' in clear_trip). Error handling is present but minimal, most failures throw McpException without recovery guidance. No pagination support despite potential for large status responses.
Clear a protection trip (alarm) on the given channel. kind is 'ocp' or 'ovp'.
Return the device identity (*IDN?) and the detected model name.
Return all channels measurements (voltage/current), setpoints, output state, CV/CC mode, and OCP/OVP protection state including trip status.
Set the output current limit (A) of the given channel. The value is clamped to the model rating.
Enable or disable over-current protection (OCP) for the given channel, optionally setting the threshold current (A).
Turn the given channel output on or off.
Enable or disable over-voltage protection (OVP) for the given channel, optionally setting the threshold voltage (V).
Output schemas not explicitly documented. Return types (IdentityResult, StatusResult) are inferred from C# method signatures, not declared in tool metadata. LLMs cannot see what fields to expect without explicit schema documentation.
Parameter 'kind' in clear_trip accepts free-form string ('ocp' or 'ovp') instead of enum. Invites hallucinated values. Should declare as enum: {"enum": ["ocp", "ovp"]}.
Channel parameter (1-3) lacks explicit constraint in schema. Description states 'availability depends on model' but no min/max bounds declared. Should add minimum: 1, maximum: 3 to schema.
| Scored | Grade | Overall | Spec posture | Rubric |
|---|---|---|---|---|
| 2026-09-23 | C | 66 | 2026-07-28+ | v2 |
Set the output voltage (V) of the given channel. The value is clamped to the model rating.
Open an interactive control panel showing live measurements for every channel, with output toggles and setpoint entry. Returns the same data as get_status.
Error handling is minimal. Failures throw McpException with generic messages ('SendFailed()') that do not guide recovery. No distinction between retryable vs fatal errors. LLM receives no actionable next steps.
No pagination or result limits documented for get_status. If device has many channels or measurements, response could grow large. Should document expected response size and offer pagination if needed.